Application
Application Area Preparation
The bonding surfaces must be smooth, dry, free of oil, grease and dust, firm and stable. The jambs and reveals have to be smoothed out according to Din 4108, part 7 for installation of PHS Fusion Variable Plus Window Tape. Especially in low temperatures, it must be ensured that all bonding surfaces are free of any frost and ice. Application surface may require priming Such as Primer 6300 e. g. for solidification of sandy surfaces.
Application at 0 to – 10 °C will reduce initial adhesion, although application is possible at such temperatures, high final strength will need longer time of contact.
Application of Tape
Measure and cut PHS Fusion Variable Plus to length with at least 5cm to spare. Peel the cover foil off the self-adhesive strip and press the strip to the back of the window frame. Proceed in this way on all sides of the window frame to be sealed. The split protective foil on the full-surface self-adhesive layer is peeled off as required and the tape carefully pressed onto the reveals substrate. Ensure that the tapes overlap in the corners. Use a pressure roller to achieve optimal initial adhesion