Technical Details
Application Area: | Up to 45 meters |
Joint-cross section approx. 10×1.5cm: | Up to 13m |
Cellularity: | Good |
Tack free time: | Approx. 5-10min |
Can be cut according to (20mm strand): | Approx. 10-12min |
Cured after (20mm strand): | Approx. 12h |
Processing temperature: | +5C to +30C |
Optimal processing temperature: | +20C to +25C |
Tensile strength (DIN 53430): | 5-6N/cm2 |
Stretching (DIN 53430): | Approx. 30% |
Shear strength (DINF 53427): | 3-4N/cm2 |
Strain at 10% compression (DIN 53421): | 1-2N/cm2 |
Water absorption (DIN 53433): | 1.4Vol.-% |
Thermal conductivity (DIN 52612): | 0.035W/mK |
Air permeability: | airtight up to 1000 Pa |
Temp. resistance of curesd strand: | -50C to +80C |
Bonding: | -50C to +100C |
Acoustic isolation: | Up to 62dB |
Building materials class (DIN 4102 part 1): | B3 |
Shelf life: | 12 months |